UL11627 AC2000V 105℃ FT2 Flame Test PVC Insulated Energy Storage Cable

  • Cable Type :  UL11627
  • Standard : UL758
  • Rated Voltage : AC2000V , DC2000V
  • Rated Temperature:  105℃
  • Flame Test : FT2 , FT1 , VW-1 (Optional)
  • Conductor:Bare or Tinned Copper Stranded
  • Insulation : PVC
  • RoHS & Reach : Approval
  • Certificate : UL
Categories: , Brand:

Description

UL11627 AC2000V 105℃ FT2 Flame Test PVC Insulated Energy Storage Cable

UL certificate, Compliant with UL758 Standard

Uniform insulation thickness for easy stripping and cutting, Passed FT2 flame test

Applied to energy storage system,battery-to-battery connection, battery-inverter connection, BMS connection, etc.

Conductor: Insulation Max Resistance
(Ω/km, 20°C, DC)
AWG Construction
(No/mm)
Nom.Dia.
(mm)
Nom.Thick.
(mm)
Nom.Dia.
(mm)
24 11/0.16 0.61 0.76 2.2 93.25
22 17/0.16 0.76 0.76 2.35 55
20 26/0.16 0.94 0.76 2.55 34.6
18 41/0.16 1.18 0.76 3.78 21.8
16 26/0.254 1.49 0.76 3.1 14.64
14 41/0.254 1.88 0.76 3.5 9.25
12 65/0.254 2.36 0.76 4 5.82
10 105/0.254 3 0.76 4.6 3.66
9 131/0.254 3.7 0.76 5.3 2.96
8 168/0.254 4.2 1.14 6.5 2.35
7 210/0.254 4.7 1.14 7 1.87
6 266/0.254 5.3 1.52 8.4 1.48
5 329/0.254 5.8 1.52 9 1.17
4 420/0.254 6.6 1.52 9.7 0.928
3 532/0.254 7.5 1.52 10.5 0.744
2 665/0.254 8.4 1.52 11.5 0.59
1 836/0.254 9.4 2.03 13.5 0.467
1/0 1045/0.254 10.5 2.03 14.6 0.37
2/0 1330/0.254 11.9 2.03 16 0.297
3/0 1672/0.254 13 2.03 17.5 0.236
4/0 2109/0.254 14.7 2.03 19.1 0.187

 

Pls send your message to us