UL3135 AC600V 200℃ FT2 Flame Test 10 AWG 14 AWG 18 AWG Silicone Wire
- Cable Type : UL3135
- Standard : UL758
- Rated Voltage : AC600V
- Rated Temperature: 200℃
- Flame Test : FT2,FT1,VW-1
- Conductor:Bare or Tinned Copper Stranded
- Insulation : Silicone Rubber
- RoHS & Reach : Approval
- Certificate : UL,CUL
Description
UL3135 AC600V 200℃ FT2 Flame Test 10 AWG 14 AWG 18 AWG Silicone Wire
• UL certificate, Compliant with UL758 Standard
• Rating : 200 deg C, 600 Vac, Horizontal flame
• Conductor : 26 AWG – 12 AWG, solid or stranded.
• Insulation : Extruded SR, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
• Use : Internal wiring of appliances where totally enclosed.
Applications
High‑Temperature Silicone Hook‑up Wire Applications
UL 3135 is a UL‑recognized silicone‑insulated hook‑up / lead wire, rated up to 200 °C and 600 V AC (nominal), with stranded (or solid) copper conductors and silicone rubber insulation
Recommended Applications
-
Internal wiring of household appliances and high‑temperature equipment — e.g. ovens, microwave ovens, electric heaters, cooking appliances operating under high heat.
-
Lighting equipment wiring — lighting fixtures, lamps, LED / high‑temperature lighting modules requiring heat‑resistant insulation.
-
Internal wiring of industrial and electronic devices — control cabinets, switchgear, electronic modules, industrial machinery, devices operating in high‑temperature, high‑stress, or chemically aggressive environments.
-
Wiring in equipment exposed to oil / chemical / high‑temperature / harsh environments — silicone insulation gives resistance to oils, acids/alkalis, high temperature, moisture, aging, making UL 3135 suitable for such demanding internal wiring.
-
Flexible routing inside devices or machinery — thanks to silicone’s softness and flexibility and high temperature rating, UL 3135 is good for compact spaces, tight bends, vibration‑prone or heat‑producing equipment.
Limitations
-
Intended for internal wiring / fixed wiring inside appliances, equipment, or machinery — not designed for outdoor, buried, or direct exposure to environment.
-
As with other hook‑up wires, not ideally suited for applications requiring heavy external mechanical stress, drag‑chain flexing, or continuous high‑flex dynamic movement.
-
For safe use at maximum performance, installation should consider ventilation or airflow (especially at elevated temperatures) to avoid degradation of silicone properties under prolonged heat.
| Conductor | Insulation | Max Resistance (Ω/km, 20°C, DC) |
|||
| AWG | No./mm | Dia.mm) | Thick.(mm) | Dia.(mm) | |
| 26 | 7/0.16 | 0.48 | 0.76 | 2.1 | 150 |
| 24 | 11/0.16 | 0.61 | 0.76 | 2.2 | 94.2 |
| 22 | 17/0.16 | 0.76 | 0.76 | 2.35 | 59.4 |
| 20 | 26/0.16 | 0.94 | 0.76 | 2.55 | 36.7 |
| 18 | 16/0.254 | 1.15 | 0.76 | 2.8 | 23.2 |
| 16 | 26/0.254 | 1.5 | 0.76 | 3.15 | 14.6 |
| 14 | 41/0.254 | 1.88 | 0.76 | 3.55 | 8.96 |
| 12 | 65/0.254 | 2.36 | 0.76 | 4.05 | 5.64 |
Pls send your message to us