UL20549 TPU Jacket AC300V 80 deg C FT2 Flame Test Drag Chain Cable Robotic Cable High-Flex Cable
- Cable Type : UL20549
- Standard : UL758,UL1581
- Rated Voltage : AC300V
- Rated Temperature: 80℃
- Flame Test : FT2,FT1,VW-1
- Conductor:Bare or Tinned Copper Stranded
- Insulation : PVC
- Jacket : TPU
- RoHS & Reach : Approval
- Certificate : UL,CUL
Description
UL20549 TPU Jacket AC300V 80 deg C FT2 Flame Test Drag Chain Cable Robotic Cable High-Flex Cable
• UL certificate, Compliant with UL758 Standard
• Rating : 80 deg C, 300 Vac, Horizontal flame.
• Insulated Conductor : 32 AWG minimum. Labeled or complying with manufacturer’s AWM procedure.
• Assembly : Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductor is not specified. A barrier layer, binders and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
• Covering : Optional, extruded over conductor assembly, 6 mils minimum thickness.
• Shield : Optional
• Jacket : Extruded TPU
• Use : Internal wiring of electronic equipment and appliances. Tags may indicate the following: “600 volts Peak for Electronic use only.”
Applications
UL 20549 – Flexible / Drag Chain / Robotic Cable
UL20549 is a UL-recognized flexible cable designed for dynamic industrial and robotic applications, supporting combined power and signal wiring in a single cable. It features stranded copper conductors with flexible, durable insulation suitable for drag chain use.
Recommended Applications
-
Drag chain and robotic wiring in industrial automation systems
-
Motor leads and control wiring in dynamic machinery
-
Combined power and signal wiring for robotic systems
-
Automation systems requiring high-flex durability and mechanical stress resistance
Limitations
-
Not suitable for fixed internal appliance wiring
-
Not suitable for outdoor, PV, or energy storage high-voltage circuits
-
Not suitable for static, non-dynamic wiring applications
| Diameter of core assembly under jacket* | Minimum average thickness | Minimum thickness at any point |
| 0.350 inch or less | 15 mils | 12 mils |
| 0.351-0.700 inch | 30 mils | 24 mils |
| 0.701-1.000 inch | 45 mils | 36 mils |
| 1.001-1.500 inch | 60 mils | 48 mils |
| 1.501-2.500 inch | 80 mils | 64 mils |
| 2.501-3.500 inch | 110 mils | 88 mils |
| 3.501 inch or greater | 140 mils | 112 mils |
| *Major diameter if cable is flat or oval. | ||
| Conductor | Insulation | Jacket | |||||
| AWG | Core | No./mm | Dia.(mm) | Thick.(mm) | Dia.(mm) | Thick.(mm) | Dia.(mm) |
| 24AWG | 2 | 11/0.16 | 0.606 | 0.38 | 1.4 | 0.38 | 3.70 |
| 3 | 3.90 | ||||||
| 4 | 4.30 | ||||||
| 5 | 4.70 | ||||||
| 6 | 5.10 | ||||||
| 22AWG | 2 | 17/0.16 | 0.756 | 0.38 | 1.6 | 0.38 | 4.10 |
| 3 | 4.30 | ||||||
| 4 | 4.80 | ||||||
| 5 | 5.30 | ||||||
| 6 | 5.70 | ||||||
| 20AWG | 2 | 26/0.16 | 0.938 | 0.38 | 1.8 | 0.38 | 4.50 |
| 3 | 4.80 | ||||||
| 4 | 5.30 | ||||||
| 5 | 5.80 | ||||||
| 6 | 6.30 | ||||||
| 18AWG | 2 | 41/0.16 | 1.179 | 0.38 | 2.0 | 0.38 | 4.90 |
| 3 | 5.20 | ||||||
| 4 | 5.80 | ||||||
| 5 | 6.40 | ||||||
| 6 | 7.00 | ||||||
| 16AWG | 2 | 65/0.16 | 1.487 | 0.38 | 2.35 | 0.38 | 5.60 |
| 3 | 6.00 | ||||||
| 4 | 6.60 | ||||||
| 5 | 7.30 | ||||||
| 6 | 8.00 | ||||||
Pls send your message to us