UL22182 TPU Jacket AC600V 90 deg C VW-1 Flame Test Drag Chain Cable Robotic Cable High-Flex Cable Control Cable for Moving Equipment

  • Cable Type :  UL22182
  • Standard : UL758,UL1581
  • Rated Voltage : AC600V
  • Rated Temperature:  90℃
  • Flame Test : FT1,VW-1
  • Conductor:Bare or Tinned Copper Stranded
  • Insulation : PVC
  • Jacket : TPU
  • RoHS & Reach : Approval
  • Certificate : UL,CUL

Description

UL22182 TPU Jacket AC600V 90 deg C VW-1 Flame Test Drag Chain Cable Robotic Cable High-Flex Cable Control Cable for Moving Equipment

UL certificate, Compliant with UL758 Standard

Rating : 90 deg C, 600 Vac, Cable flame, 60C wet (optional).

Insulation : Labeled

Assembly : Thirty insulated singles, twisted pairs or groups of twisted singles twisted together, or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer, shielding and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size

Filler : Optional, in accordance with the Standard.

Separator : Optional. May be applied around each conductor.

Shield : Optional, in accordance with the Standard.

Jacket : Extruded TPU, 70 mils average thickness, 63 mils minimum thickness at any point

Use : External Wiring.

Application

UL 22182 – Flexible / Drag Chain / Robotic Cable Applications

UL22182 is a UL-recognized high-flex cable for robotic and industrial automation applications, with stranded copper conductors and robust insulation. It is intended for wiring in environments with repeated bending, torsion, and continuous motion.

Recommended Applications

  • Robotic arms and automated manufacturing equipment

  • Drag chain wiring for machinery

  • Motors, actuators, and dynamic motion systems in industrial robots

  • Control wiring in automation systems exposed to frequent movement

Limitations

  • Not suitable for fixed internal appliance wiring

  • Not suitable for outdoor, PV, or energy storage high-voltage circuits

  • Not suitable for low-flex or static wiring applications

Conductor Insulation Jacket
AWG Core No./mm Dia.(mm) Thick.(mm) Dia.(mm) Thick.(mm) Dia.(mm)
20AWG 2 26/0.16 0.94 0.76 2.55 1.78 9.0
3 9.4
4 10
5 11
18AWG 2 41/0.16 1.18 0.76 2.75 1.78 9.3
3 9.8
4 10.5
5 11.6
16AWG 2 65/0.16 1.49 0.76 3.1 1.78 10.1
3 10.5
4 11.4
5 12.6
14AWG 2 41/0.254 1.87 0.76 3.5 1.78 11
3 11.5
4 12.4
5 13.8
12AWG 2 65/0.254 2.36 0.76 4.0 1.78 12
3 12.6
4 13.6
5 15.3
10AWG 2 105/0.254 3.10 0.76 4.65 1.78 13.3
3 14
4 15.3
5 17.2

 

Pls send your message to us