UL2517 AC300V 105℃ VW-1 Flame Test Multi-Core PVC Insulation and jacket wire

  • Cable Type :  UL2517
  • Standard : UL758,UL1581
  • Rated Voltage : AC300V
  • Rated Temperature:  105℃
  • Flame Test : VW-1
  • Conductor:Bare or Tinned Copper Stranded
  • Insulation : PVC
  • Jacket : PVC
  • RoHS & Reach : Approval
  • Certificate : UL,CUL

Description

UL2517 AC300V 105℃ VW-1 Flame Test Multi-Core PVC Insulation and jacket wire

UL certificate, Compliant with UL758 Standard

Rating : 105 deg C, 300 Vac, Cable Flame.

  Insulated Conductor : Labeled or complying with Manufacturer’s AWM Procedure. 40 AWG minimum.

Assembly : Consists of two or more singles, twisted pairs or groups of twisted singles twisted together. The singles or groups of singles may be laid parallel forming a flat, oval or round cable. The lay of the conductors are not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.

Shield : Optional

Covering : Optional

Jacket : Extruded PVC

•  Braid : Optional

Use : External interconnection of electronic equipment or internal wiring of electronic equipment or appliances. Tags may also indicate the following: “600 Volts peak for Electronic Use Only”.

Diameter of Core Assembly under Jacket@ Minimum Average Thickness Minimum Thickness at any point
0.700 inch or less 30 mils 24 mils
0.701 – 1.000 inch 45 mils 36 mils
1.001 – 1.500 inch 60 mils 48 mils
1.501 – 2.500 inch 80 mils 64 mils
@ – Major diameter if cable is flat or oval.

 

Conductor Insulation jacket
AWG Core No./mm Dia.(mm) Thick.(mm) Dia.(mm) Thick.(mm) Dia.(mm)
26AWG 2 7/0.16 0.48 0.38 1.3 0.76 4.2
3 4.4
4 4.7
5 5.3
24AWG 2 11/0.16 0.606 0.38 1.4 0.76 4.4
3 4.6
4 5
5 5.6
22AWG 2 17/0.16 0.756 0.38 1.6 0.76 4.8
3 5.1
4 5.5
5 6.1
20AWG 2 26/0.16 0.938 0.38 1.8 0.76 5.2
3 5.5
4 6
5 6.7
18AWG 2 41/0.16 1.179 0.38 2.0 0.76 5.6
3 5.9
4 6.5
5 7.3
16AWG 2 65/0.16 1.487 0.38 2.35 0.76 6.4
3 6.8
4 7.4
5 8.3

 

Pls send your message to us