UL3289 AC600V 150℃ FT2 Flame Test XLPE Insulation Single Wire Alternator Hook up
- Cable Type : UL3289
- Standard : UL758
- Rated Voltage : AC600V DC750V
- Rated Temperature: 150℃
- Flame Test : FT2,FT1,VW-1
- Conductor:Bare or Tinned Copper Stranded
- Insulation : XLPE
- RoHS & Reach : Approval
- Certificate : UL
Description
UL3289 AC600V 150℃ FT2 Flame Test XLPE Insulation Single Wire Alternator Hook up
• UL certificate, Compliant with UL758 Standard
• Rating : 150 deg C, 600 Vac, 750 Vdc, Horizontal flame.
• Conductor : 30 AWG – 750 kcmil, solid or stranded. Recognized Component – Magnet Wire (OBMW2), rated 200 degrees C (ANSI Type MW35) may be used.
• Insulation : Extruded XLPE or XLPO.
• Use : For use as Motor Leads or Internal Wiring of Appliances.
Applications
UL3289 is an AWM/UL-recognized hook-up and lead wire, rated 150 °C and 600 V AC, with stranded or solid copper conductors and XLPE insulation. It is intended for fixed internal wiring where high temperature resistance, mechanical durability, and flame resistance are required
Recommended Applications
-
Internal wiring of household appliances such as refrigerators, ovens, air conditioners, washing machines, and heating devices
-
Motor lead wires for fans, pumps, compressors, and other electric motors
-
Wiring inside transformers, power supplies, and electronic modules
-
Internal wiring of control panels, switchgear, and automation equipment
-
Internal wiring for lighting equipment, ballasts, and lighting fixtures
-
Appliance and electronic device internal connections where high-temperature and standard-voltage performance is required
Limitations
-
Not suitable for high-voltage mains wiring above 600 V
-
Not suitable for outdoor, PV, energy storage, or EV high-voltage circuits
-
Not suitable for dynamic flexing, cable carriers, or robotic high-flex applications
-
Designed only for fixed internal wiring under its rated conditions
| Conductor size | Minimum average thickness | Minimum thickness at any point |
| 30-9 AWG | 30 mils | 27 mils |
| 8 AWG | 45 mils | 41 mils |
| 7-2 AWG | 60 mils | 54 mils |
| 1-4/0 AWG | 80 mils | 72 mils |
| 250-500 kcmil | 95 mils | 86 mils |
| 501-750 kcmil | 110 mils | 99 mils |
| Conductor | Insulation | Max Resistance (Ω/km, 20°C, DC) |
|||
| AWG | No./mm | Dia.mm) | Thick.(mm) | Dia.(mm) | |
| 30 | 7/0.10 | 0.3 | 0.76 | 1.9 | 381 |
| 28 | 7/0.127 | 0.38 | 0.76 | 2 | 239 |
| 26 | 7/0.16 | 0.48 | 0.76 | 2.1 | 150 |
| 24 | 11/0.16 | 0.61 | 0.76 | 2.2 | 94.2 |
| 22 | 17/0.16 | 0.76 | 0.76 | 2.35 | 59.4 |
| 20 | 26/0.16 | 0.94 | 0.76 | 2.55 | 36.7 |
| 18 | 16/0.254 | 1.15 | 0.76 | 2.8 | 23.2 |
| 16 | 26/0.254 | 1.5 | 0.76 | 3.15 | 14.6 |
| 14 | 41/0.254 | 1.88 | 0.76 | 3.55 | 8.96 |
| 12 | 65/0.254 | 2.36 | 0.76 | 4.05 | 5.64 |
| 10 | 105/0.254 | 3.1 | 0.76 | 4.9 | 3.546 |
| 8 | 168/0.254 | 4.25 | 1.15 | 6.6 | 2.23 |
| 6 | 266/0.254 | 5.35 | 1.15 | 7.8 | 1.403 |
| 4 | 420/0.254 | 6.7 | 1.15 | 9.1 | 0.882 |
| 2 | 665/0.254 | 8.45 | 1.53 | 11.6 | 0.5548 |
| 1 | 836/0.254 | 9.5 | 2.03 | 13.7 | 0.4398 |
| 1/0 | 1045/0.254 | 10.6 | 2.03 | 14.9 | 0.3487 |
| 2/0 | 1330/0.254 | 12 | 2.03 | 16.2 | 0.2766 |
| 3/0 | 1672/0.254 | 13.45 | 2.03 | 17.7 | 0.2194 |
| 4/0 | 2109/0.254 | 14.85 | 2.03 | 19.1 | 0.1722 |