UL3661 AC1100V 180℃ FT2 Flame Test Silicone Insulated Wire
- Cable Type : UL3661
- Standard : UL758
- Rated Voltage : AC1100V
- Rated Temperature: 180℃
- Flame Test : FT2,FT1,VW-1
- Conductor:Bare or Tinned Copper Stranded
- Insulation : Silicone Rubber
- RoHS & Reach : Approval
- Certificate : UL,CUL
Description
UL3661 AC1100V 180℃ FT2 Flame Test Silicone Insulated Wire
• UL certificate, Compliant with UL758 Standard
• Rating : 180 deg C, 1100 Vac, Horizontal flame.
• Conductor : 16 AWG – 750 kcmil solid or stranded
• Separator : Optional
• Insulation : Extruded SR
• Covering : Optional
• Use : Internal wiring of appliances.
| Conductor size | Minimum average thickness | Minimum thickness at any point |
| 16-4 AWG | 37 mils | 33 mils |
| 3-3/0 AWG | 60 mils | 54 mils |
| 4/0 AWG-450 kcmil | 80 mils | 72 mils |
| 500-750 kcmil | 105 mils | 95 mils |
| Conductor | Insulation | Max Resistance (Ω/km, 20°C, DC) |
|||
| AWG | No./mm | Dia.mm) | Thick.(mm) | Dia.(mm) | |
| 16 | 26/0.254 | 1.49 | 0.94 | 3.5 | 14.6 |
| 14 | 41/0.254 | 1.87 | 0.94 | 3.9 | 8.96 |
| 12 | 65/0.254 | 2.36 | 0.94 | 4.4 | 5.64 |
| 10 | 105/0.254 | 3.09 | 0.94 | 5.2 | 3.546 |
| 8 | 168/0.254 | 4 | 0.94 | 6.1 | 2.23 |
| 6 | 266/0.254 | 5 | 0.94 | 7.1 | 1.403 |
| 4 | 420/0.254 | 6.4 | 0.94 | 8.5 | 0.882 |
| 2 | 665/0.254 | 8 | 1.53 | 11.4 | 0.5548 |
| 1 | 836/0.254 | 8.95 | 1.53 | 12.3 | 0.4398 |
| 1/0 | 1045/0.254 | 10.02 | 1.53 | 13.5 | 0.3487 |
| 2/0 | 1330/0.254 | 11.3 | 1.53 | 14.8 | 0.2766 |
| 3/0 | 1672/0.254 | 12.7 | 1.53 | 16.4 | 0.2194 |
| 4/0 | 2109/0.254 | 14.3 | 2.03 | 19.5 | 0.1722 |
Pls send your message to us